SerVision MVG 400 Guide de l'utilisateur Page 156

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 190
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 155
SerVision MVG 400 System Guide
Resetting the Unit 156
3. Place the jumper on pins 2 and 3 of the RS232/485 connector.
Figure 149: Connectors for shorting activators and sensors
Figure 150: Jumper connected to pins 2 and 3
4. Reconnect the power to the unit. When the startup process is completed (the Power LED
on the front of the unit flashes at frequent intervals), the default factory settings are
restored.
5. Disconnect the power from the unit again.
6. Remove the jumper from the RS232/485 connector.
7. If you disconnected a PTZ controller before performing this procedure, reconnect the
controller.
8. Reconnect the power to the unit.
Erasing Recorded Video
Recorded video is normally stored on the hard drive until one of the following occurs:
The video is over-written by newer video.
Pin 2 Pin 3
RS232/485
connector
Vue de la page 155
1 2 ... 151 152 153 154 155 156 157 158 159 160 161 ... 189 190

Commentaires sur ces manuels

Pas de commentaire