SerVision Embedded Video Gateway System Guide
Configuring System Settings 21
SMS on System Start: Sends SMS notifications to all SMS recipients whenever the Video Gateway starts
running. For information about defining SMS recipients, see SMS and E-mail Notifications, page 58.
ADAM Sensors: Enables the activation of sensors that are connected to the Video Gateway unit through an
ADAM module. For additional information, see Configuring Sensor and Activator Settings, page 110.
IA Sensors and Activators: Enables the activation of sensors and activators that are connected to the Video
Gateway unit through an IA 3126-2 relay board. For additional information, please refer to your unit’s
installation manual.
Maximum Recording Length: Automatically erases recorded video after a specified period of time.
Configuring General System Settings
To adjust the general system settings:
1. In the Main Menu, under System, click General. The General System Settings screen opens:
Figure 17: General System Settings screen (MVG)
2. Fill in the fields as follows: