SerVision MVG 400 System Guide
Troubleshooting 189
13. Problem:
The LEDs on the front panel of the unit light up, but the unit cannot be accessed by any
external devices.
Solutions:
Restart the unit and observe the LEDs on the front panel. The normal power-up sequence
includes a number of flashes of these LEDs: The Power (right) LED starts out green,
flashes orange, turns green again, flashes five times, and, finally, when the start-up
process is completed and the unit is operating normally, blinks every second. Before the
five flashes of the Power LED, the HDD (left) LED flashes red once.
• If the unit completes part of the start-up sequence and then restarts without
completing the process – the unit restarts before the HDD LED flashes or after the
five flashes of the Power LED – try reinstalling the firmware using Catch Boot.
Additional information: Catch Boot Option, page 168
• If the unit completes the entire start-up sequence and then restarts, try restoring the
factory settings.
Additional information: Restoring Factory Settings, page 155
• If the Power (right) LED displays as a solid green at power-up, or displays as a solid
green and then a solid orange but does not flash, the unit is unusable. Contact your
vendor for additional assistance.
14. Problem:
The unit does not turn on – the LEDs on the front panel do not light up and the unit
cannot be accessed by any external devices.
Solutions:
• Check the power connections and cables.
• Contact your vendor for assistance.
Note: Do not open the MVG 400. It contains no user-serviceable parts.
15. Problem:
The unit disconnects and reconnects from the MultiClient every few minutes.
Solutions:
• Check that the external LAN connection is connected to the Ethernet(Out) connector
on the rear of the unit.
• Contact your vendor for assistance.